In your customer interface, you have the possibility to create as many schedules and programs as you wish.
For each schedule, if you are in Multizone, you have the possibility of entering the set point temperatures and the pilot wire orders in your schedule.
Depending on whether the schedule is applied to a zone managed by the thermostat or only by modules, the thermostat zone will follow temperature instructions and the secondary zones with modules will follow the pilot wire orders.
Comfort Order
The internal thermostat of the radiator has the value set on the radiator as its set point.
Comfort -1° Order*
The internal thermostat of the radiator has the value set on the radiator -1°C as its set point.
Comfort -2° Order*
The internal thermostat of the radiator has the value set on the radiator -2°C as its set point.
Eco Order
The radiator's internal thermostat has the value set on the radiator -3 or 3.5°C as its set point, depending on the manufacturer.
Antifreeze Order
The internal thermostat has a set point between 6°C and 8°C depending on the manufacturer.
Stop Order
The radiator receives no instructions.
*Comfort -1 and comfort -2 orders are only available on 6-order pilot wire radiators. If your radiator is only 4 orders, those orders should not be used and the radiator will apply "Confort".